Tables are provided for Soil Electrical Resistivity values for different Soil Types, Geology, and Surface Layers Materials in Substations.
view more20081028 · For the step and touch potential substation grounding calculation, we are debating for the surface material to be used. I suggested the crushed rock should be the surface material to be used, my colleagues suggested should be the asphalt, as they are telling me that the crushed rock bottom is steel grating, and below the steel grating is an …
view more2020518 · Interior access road in the substation is usually a crushed rock and occasionally installed with bituminous materials. For larger substations, the access road may consist of an excavating fill with aggregate base course and surfacing material for the entire yard and 3 t0 5 ft beyond the fence.
view more2 · The following steps were established by the IEEE Standard 80-2000 for the design of the ground grid: Step#1: Field Data Collection, Step#2: Earthing Grid Conductor Sizing, Step#3: Calculation of tolerable touch and step voltages, Step#4: Preliminary design of grounding system, Step#5: Calculation of of the preliminary Grid Resistance, RG, of ...
view moreThis report explains how to perform accurate earth fault current analysis for substations connected by cable transmission lines. Earth fault currents for simple cable and overhead transmission lines are explained first. Next, two case studies involving hybrid cable transmission lines are presented.
view more2 · Testing procedure for earthing systems based on Fall of Potential Method, touch and step voltage measurement, safety and recommended equipment.
view moreSubstations are a vital part of the electric power system and therefore require properly designed grounding systems to ensure protection of persons working in the vicinity of earthed facilities from danger of electric shock, safeguard of equipment against unnecessary breakdowns and maintain steady functioning of the entire electrical system. When …
view moreReach touch voltages are different to touch voltages and useful when there is a certainty that conductors are farther away than a person could touch.
view more2018624 · My utility in Ontario, Canada has always used crushed rock / large gravel in switchyards - and a number of years back they stipulated that employees were henceforth to wear dielectrically resistive footwear when working in electrical environments.
view moreBased on over 30 years' experiences in design, production and service of crushing and s